Commands for displaying environmental status the environment commands enable you to display all environment information shelf environment status and chassis environment status.
Netapp 7 mode check power supply status.
For clustered ontap systems check cluster show and storage failover show to confirm cfo sfo is configured enabled.
Data ontap runs the environment commands under the following conditions.
Enter cf enable and monitor with cf status.
The command environment status chassis only looks at the storage appliance itself its onboard power supplies and fans etc.
Netapp active iq is a digital advisor that uses aiops to provide actionable insights and automate the proactive care and optimization of your netapp environment.
Downgrading software versions between minor releases when downgrading a cluster from data ontap 8 2 1 to data ontap 8 2 ontap clears the history of deleted switches.
System health system connectivity shelf show instance.
Physically unplug the cables from power supplies on the back of the storage systems and shelves to avoid any electrical issues when external power is restored.
It looks like you have 2 shelves that have some type of issue.
Display the status of shelves from the cluster level view.
For 7 mode ha pairs.
Use the instance parameter to display detailed information about each shelf.
Use other parameters to filter the list of alerts for example by policy status enabled or not health monitor alert and so on.
Read more launch aiq arrow forward.
This command is available to cluster administrators at the admin privilege level.
Display detailed information about each shelf including the shelf s uuid and id its connected nodes and the number of paths to the shelf.
Display the status of shelves from the cluster level view including the shelf s uuid and id its connected nodes and the number of paths to the shelf system health system connectivity shelf show note.
The sp commands at the admin privilege level enable you to display events logs and status information for node power batteries sensors field replaceable units frus or the sp itself.
System health system connectivity shelf show.
Cluster1 storage shelf show module operational shelf name shelf id serial number model type status 1 1 1 6000270148 ds2246 iom6 critical 1 3 3 6000001183 ds2246 iom6 normal 1 4 4 6000003844 ds2246 iom6 normal 1 5 5 shj000000013a9e ds4246 iom6 normal 1 6 6 shj000000013a84 ds4246 iom6 normal 1 7 7 6000005555.
Display power information for cluster and management switches.